Values measured : Peak Or RMS Value
• Units : mm/sec or in/sec (*1Factory Set)
• Range : 0 to 50 mm/sec Peak (Factory Preset)
II Displacement
• Values measured : Peak to Peak
• Units : microns or mils (*1Factory Set)
• Range : 0 to 500 microns (Factory Preset)
I Accelerometer : 100mv/g (+/- 10%)
II Velocity Sensor : 4 mv/mm/sec (+/- 10%)
I Frequency Ranges : Factory preset (±3dB)
• 2 to 1000 Hz
• 2 to 5000 Hz
• 2 to 10000 Hz
• 2 to 20000 Hz
• 10 to 1000 Hz
• 10 to 10000 Hz
II Display
• Output display : "5 seven-segment displaysa. Right most 3 digits for numerical valueb. All 5 digits
to indicate message strings”
• Measured parameters : Velocity / Displacement (*1Factory Set)
• Indicators : 1 Bi colour LED Pk/RMS/Pk-Pk,
Ch1 - Safe/Alert/Danger, Ch2 - Safe/Alert/Danger
1 Bi colour LED - Velocity/Displacement,
in/sec/mils, mm/sec/micron (*1Factory Set)
III Key Pad : "Keypad with integrated LEDsa. 4 tactile keysb. LEDs fori. Channel selected for
displayii. Velocity or Displacementiii. Units: mm/s or in/siv. Units: µm or milv.
Channel status"
IV Output : 4-20 mA = ch1 and ch2 individual
• Through rear panel terminals : Buffered output of sensor output Ch1 and Ch2 on rear terminal blocks
• Relay Output : Relay contact - 2 No.s For Alert and Danger
Relay contact details - 5A, 240VAC / 220VDC
Sensor failure - On Display
• Communication port (Optional) "a. MODBUS over RS485 b. Modes: RTU and ASCII (*1Factory Set)"
V Monitor accuracy : ±2% of FSD
(Measurement Range
VI Operating voltage : 230V/115V ±10% @ 50Hz, Factory Selectable
VII Operating conditions
• Temperature range : 0 to 70ºC upto 95% humidity (non condensing)
I Panel mounted : Size: 144(H) x 72(W) x 180(D) mm
• Front fascia/Bezel : 144 (H) X 72 (W) mm
• Cutout : 138 (H) X 68 (W) mm
II Field mounted:
• Enclosure size : 330 (H) x 165 (W) x 95 (D)
• Construction : Aluminium Die-cast with IP65 Keypad
• Protection : IP65
• Cable Entry : 7 nos PG9 suitable for 4 to 8 mm OD cable